Skip to main content
This reference architecture shows how to run Alluxio on CoreWeave Kubernetes Service (CKS) to cache data from object storage outside CoreWeave, such as Azure Blob Storage or Google Cloud Storage (GCS). Alluxio caches the data on the local NVMe disks of GPU Nodes, so repeated reads come from local disk instead of the remote store. Alluxio is third-party software that you deploy and operate. CoreWeave validated this pattern in a proof of concept (PoC) but doesn’t provide or manage Alluxio. If your data is already in CoreWeave AI Object Storage, use Local Object Transport Accelerator (LOTA) instead.

Architecture

The architecture has the following components: etcd is sensitive to fsync latency, and Distributed File Storage has no per-tenant latency guarantee. See Distributed File Storage performance considerations.

Prerequisites

  • A CKS cluster with a CPU Node Pool for the Alluxio control plane and a GPU Node Pool whose instance type has multiple local NVMe disks.
  • kubectl with the cluster’s kubeconfig, the CoreWeave Intelligent CLI (cwic) with an API access token, and jq.
  • Alluxio, deployed with access to your remote object store.

Configure cache disks that survive a reboot

By default, Node-local storage doesn’t survive a reboot. To keep the Alluxio cache across reboots, set the storage_config Node Pool parameter under spec.nodeParameters to a layout with flush: "false". The validated layout uses one disk for /mnt/local, which also holds container layers and emptyDir volumes, and gives each remaining NVMe disk its own encrypted XFS filesystem (just a bunch of disks, or JBOD).
Before you use a flush-disabled storage configuration, note the following:
  • Turn on TPM. Every encrypted mount point with flush: "false" also needs tpm: "true", which stores the disk encryption key in the Node’s Trusted Platform Module (TPM). If any mount point is missing it, CKS rejects the whole configuration, and the Node boots without its local disks. tpm: "true" works only on instance types that have a TPM, so confirm support for your instance type with CoreWeave Support before you roll it out.
  • Migrate existing Nodes in two phases. A flush-disabled configuration keeps the existing disk layout instead of replacing it. If you apply it directly to Nodes that already use another storage layout, the Nodes can fail to become Ready and move to triage. New Nodes can use the flush-disabled configuration directly. On existing Nodes, run the configuration procedure that follows this warning twice:
    1. This first run wipes and recreates every filesystem, so drain the Nodes and copy off any data you need to keep. Then run it on every Node, using a configuration with system_flush and every flush set to "true" and tpm set to "false".
    2. After every Node finishes the first run, run it again with the flush-disabled configuration.
  • Expect no disk redundancy. JBOD disks have no RAID redundancy, so each disk can fail independently. Treat the cache as disposable, not as durable storage.
  • Keep labels short. Keep each fs_label unique within its first 12 characters, the XFS label limit.
To apply the configuration, do the following:
  1. Save the storage configuration as storage-config.json. This excerpt shows /mnt/local and the first cache disk. Add one entry for each remaining cache disk, incrementing the mount point and fs_label (/lota_cache_02 and lotacache-02, and so on). The validated layout on an eight-disk Node has seven cache disks.
    storage-config.json (excerpt)
  2. Validate the JSON, encode it in Base64, and stage it on the Node Pool. Replace [NODEPOOL-NAME] with your Node Pool’s name:
    To confirm the staged value, decode it:
    The output matches storage-config.json. With the default OnSpecUpdate update strategy, the patch stages the configuration without changing running Nodes. With Manual, promote it with cwic nodepool upgrade [NODEPOOL-NAME].
  3. List the Nodes that need reconfiguration:
  4. Drain one test Node, then apply the configuration with a reconfigure reboot. Replace [TEST-NODE] with the Node’s name:
    For details about these flags, see Apply Node Pool updates.
  5. After the reconfigure reboot completes and the Node is Ready, confirm that each mount point is its own encrypted XFS filesystem. Run these commands on the Node, or from a privileged Pod scheduled on it:
    An eight-disk Node shows eight encrypted XFS filesystems. The lsblk command lists disks in device order, not mount-point order, so check each mount point.
  6. Drain and reconfigure the remaining Nodes in small batches. The cwic node reboot command accepts several space-separated Node names.
To remove the storage configuration from the Node Pool, set the storage_config parameter to null:
Then drain and reconfigure the Nodes as in steps 3, 4, and 6. The Nodes return to the default layout, which wipes every local disk, including the cache disks.

Keep cache Pods from blocking Node maintenance

Long-running Alluxio cache Pods on GPU Nodes that a DaemonSet doesn’t manage count as active workloads. They keep the Node’s CWActive condition at True, which blocks Node Pool scale-down and fleet lifecycle automation, and they delay pending Node lifecycle transitions, such as maintenance reboots. For more information, see Active Nodes and stalled transitions. To keep cache Pods from blocking maintenance, do the following:
  • Don’t tolerate all taints. If cache Pods tolerate every taint, including the CKS eviction taints, they skip graceful eviction and can schedule back onto the Nodes that CoreWeave is trying to drain. Tolerate only the taints that the cache Pods need.
  • Label cache Pods as interruptible. Add the qos.coreweave.cloud/interruptable: "true" label to the Pod templates of the Alluxio worker and FUSE Pods. CKS doesn’t count Pods with this label as active, and the label suits a cache that refills from the remote store. The key is spelled interruptable for historical reasons. For more information, see Interruptible workloads.

Proof-of-concept results

These results come from the CoreWeave PoC and aren’t a performance commitment. Results depend on object sizes, access patterns, the remote region, and the network path, so measure with your own workload. The PoC used two turin-gp-l CPU Nodes, with six 7.68 TB NVMe disks on each Node as Alluxio cache, and read from Azure Blob Storage. It ran Alluxio Enterprise AI 3.8 with Alluxio operator 3.7.6 and LOTA turned off. CoreWeave tested the cache-disk storage configuration on this page separately from the PoC. When the PoC removed one worker, clients kept reading without interruption and the cache hit ratio dropped from 100% to about 94%. After the worker rejoined, the hit ratio returned to 100%.